VERIFIEDPassed the Codex final verification and publication gate. Evidence-verification cutoff: 2026-08-14. AI was used for research and drafting; the existence of all 3 cited sources was verified at the original page, followed by blind grading, adversarial audit, and build validation. Methodology v1.0.
Verdict No. 2531 · Search date 2026-08-14 · Methodology v1.0

Taurolidine-heparin catheter lock,
does it really help with Prevention of catheter-related bloodstream infection in hemodialysis through a central venous catheter?

30-Second Summary
B
Evidence Grade B · 72 · Safety caution
Taurolidine-based lock reduced infection in an independent trial, although its formulation differed from LOCK IT-100.
Overall safety in the trial was comparable with heparin and most adverse events were mild or moderate. Prior heparin-induced thrombocytopenia, hypersensitivity, and bleeding risk require prescribing oversight and monitoring.
What the
research shows
The grade is B. In the 795-participant full analysis of LOCK IT-100, blinded-adjudicated catheter-related bloodstream infection occurred in 9/397 (2.3%) with taurolidine-heparin versus 32/398 (8.0%) with heparin, HR 0.29 (95% CI 0.14-0.62). A separately funded RCT also reduced infections with a different formulation, while LOCK IT-100 was manufacturer-sponsored and stopped early for efficacy, giving B with 72 points.
What the
ads claim
The decisive point is fewer culture-confirmed bloodstream infections, not merely an antimicrobial mechanism. An independent trial exists, but its formulation differed, so it is not exact replication of the same product.
*

Useful facts when choosing a product

  • The study formulation contained taurolidine 13.5 mg/mL, citrate 3.5%, and heparin 1,000 U/mL; the control contained heparin 1,000 U/mL.
  • The lock was instilled after dialysis and withdrawn before the next dialysis session.
  • The target brief's NCT03595514 was corrected to NCT02651428 after checking the paper and ClinicalTrials.gov.
  • No duplicate verdict for this formulation and dialysis-catheter infection claim, PMID 37678222, or DOI 10.2215/CJN.0000000000000278 was found in the existing list.
ID

Chamgap Semantic Classification Code

Candidate index · review held

UNK.taurolidine-ml-plus-heparin-1.UNK.catheter-related-bloodstream-infection-in-hemodialysis-through-a-central-venous-catheter.prevent.active

Unknown > Taurolidine /mL plus heparin 1 > Unknown > catheter-related bloodstream infection in hemodialysis through a central venous catheter > Occurrence-prevention claim > Active comparator

An automated migration candidate, not an issued permanent code; exact claim scope remains under review. This machine-generated migration candidate helps retrieval but is not a permanent assignment. The original verdict ID and URL remain authoritative.

Download semantic index (JSON) · Codebook v1

Gap Measurement · Verdict 2531 · B 72
What advertising claims
What independent, higher-quality research supports
△ GAP
01

What the research actually shows

LOCK IT-100 was a randomized, double-blind, active-controlled phase 3 trial at 70 US sites, with 795 participants in the full efficacy population. Its paper states, "This study was sponsored by CorMedix Inc." and three company employees were coauthors. Winnicki et al. 2018 independently randomized 106 patients in NCT02789501 to a different taurolidine regimen, TauroLock-Hep500 twice weekly plus TauroLock-U25,000 once weekly, or 4% citrate. Infection occurred as 6 events in 6/52 patients versus 18 events in 13/54, 0.67 versus 2.7 per 1,000 catheter-days, IRR 0.25 (95% CI 0.09-0.63), and dysfunction also favored taurolidine. Exit-site and tunnel infections and cardiovascular hospitalization were neutral; deaths were numerically unfavorable at 4 versus 2, though adjudicated unrelated to the lock regimen. The funding statement was, "This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors." Study solutions were purchased from TauroPharm.

02

Why this is classified as B (72)

A 795-participant phase 3 trial showed a large reduction in blinded-adjudicated bloodstream infection, and an independently funded RCT of a different formulation also reduced infection. Lack of exact product replication and early stopping limit the result to B with 72 points.

Counterpoint. B does not mean infection prevention failed. An independent trial was favorable, but its different formulation was not exact replication of LOCK IT-100.

Rejudgment record. Cross-check applied — We cross-checked outcomes, formulations, registrations, funding, and early stopping against LOCK IT-100 with NCT02651428 and Winnicki with NCT02789501.

Stored scoring profile
EndpointHHard endpoint - actual events such as death
ReplicationR1Single confirmatory trial
IndependenceI1Mixed funding sources
Effect sizeE+Meets the clinically important threshold

Stored derived and displayed grades match; this is not a current recalculation or validity check (B).

▦

Sub-claim grades by effect

This ingredient is marketed for several effects. A single overall grade blends strong and weak claims together, so each effect is graded separately here. The overall grade reflects the strongest disconfirming or core claim.

Effect (sub-claim)GradeBasis
Taurolidine-heparin lock reduces dialysis catheter-related bloodstream infection.BIn 795 participants, rates were 2.3% versus 8.0%, HR 0.29.
Taurolidine-heparin lock reduces catheter removal for any reason.DThis secondary outcome did not differ significantly between groups.
✓

Cross-check — AI research and Codex final gate

AI was used for research and drafting. Blind grading, adversarial audit, and the methodology boundary rules were then reapplied before Codex performed the final evidence, grade, copy, and build checks. If a grade cannot be narrowed, both evidence positions and their reasons are published.
03

Evidence Table

StudyDesignSampleFundingEndpointResultWeight
Agarwal et al., LOCK IT-100 2023Randomized double-blind active-controlled phase 3 trial at 70 US sites806 enrolled; 795 in the full efficacy analysis (397/398)Original statement: "This study was sponsored by CorMedix Inc."; three company employees were coauthorsTime to catheter-related bloodstream infection confirmed by a blinded clinical adjudication committee9/397 (2.3%) versus 32/398 (8.0%); HR 0.29 (95% CI 0.14-0.62), P<0.001Large registered hard-outcome trial, but manufacturer-only and stopped early for efficacy
Winnicki et al., taurolidine-based lock RCT 2018Prospective multicenter randomized trial versus 4% citrate106 participants (52 taurolidine/54 citrate)Original statement: "This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors." Study solutions were purchased from TauroPharm.Catheter-related infection, dysfunction, and costSix infections in 6/52 versus 18 in 13/54; 0.67 versus 2.7 per 1,000 catheter-days, IRR 0.25 (95% CI 0.09-0.63). Dysfunction favored taurolidine; exit-site and tunnel infections and cardiovascular hospitalization were neutral, while deaths were numerically unfavorable at 4 versus 2 but adjudicated unrelated to the lock regimen.Independently funded RCT, but with a formulation different from LOCK IT-100
§

Receipt — 3 References

All 3 cited sources were verified for existence at the original page (as of 2026-08-14).

Agarwal AK, Roy-Chaudhury P, Mounts P, et al. Taurolidine/Heparin Lock Solution and Catheter-Related Bloodstream Infection in Hemodialysis: A Randomized, Double-Blind, Active-Control, Phase 3 Study. Clin J Am Soc Nephrol. 2023;18(11):1446-1455. PMID: 37678222. PMCID: PMC10637459. DOI: 10.2215/CJN.0000000000000278. NCT02651428.
checked
ClinicalTrials.gov. Study Assessing Safety & Effectiveness of a Catheter Lock Solution in Dialysis Patients to Prevent Bloodstream Infection. NCT02651428.
checked
Winnicki W, Herkner H, Lorenz M, et al. Taurolidine-based catheter lock regimen significantly reduces overall costs, infection, and dysfunction rates of tunneled hemodialysis catheters. Kidney Int. 2018;93(3):753-760. PMID: 28890326. DOI: 10.1016/j.kint.2017.06.026. NCT02789501.
checked
Research and draft: AI used · Cross-check: blind grading and adversarial audit
Final verification and publication gate: Codex · Evidence date: 2026-08-14 · Corrections: none
↗

Cite this verdict

Taurolidine-heparin catheter lock x prevention of bloodstream infection in hemodialysis Evidence Grade B card
[Chamgap] Taurolidine-heparin catheter lock x prevention of bloodstream infection in hemodialysis — Evidence Grade B·72. 3 cited sources checked. Source: https://chamgap.com/en/verdicts/immunity/taurolidine-heparin-lock-hemodialysis-catheter-bloodstream-infection/ · CC BY 4.0

CC BY 4.0 — free to use with attribution; do not distort grades, numbers, or verdict meaning.

!

What this document does and does not do

Chamgap is an information source. It reports what research has and has not confirmed; it does not tell readers what to take or buy. That decision belongs to readers and, when needed, medical or legal professionals. This verdict reflects literature available up to the search date and may change as new research appears. Nothing here is medical advice.
↑